ACS550-02-486A-4 ABB ACS550-02-486A-4 Free-standing units.

Product Name: Inverter.
Model: ACS550-01-486A-4.
3-phase ACS550-02-486A-4 supply voltage 380 to 480 V.
Free-standing units.
Frame ACS550-02-486A-4 size: R8.
Typical motor power in 460 V at normal use: 400hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 486A.
Typical motor power in 400 V at heavy-duty use: 200KW.
Typical motor power in 460 V at heavy-duty use: 350HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 414A.
Typical motor power in 400 V at normal use: 250kw.
ABB ACS550-02-486A-4
Product Name: Inverter.
Model: ACS550-01-645A-4.
Typical motor power in ABB ACS550-02-486A-4 460 V at heavy-duty use: 500HP.
Free-standing units.
Typical motor power in 400 V at normal use: 355kw.
Typical ABB ACS550-02-486A-4 motor power in 460 V at normal use: 500hp.
Continuous rms current. 10% ABB ACS550-02-486A-4 overload is allowed for one minute in ten minutes: 645A.
Typical motor power in 400 V at heavy-duty use: 315KW.
3-phase supply voltage 380 to 480 V.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 590A.
Frame size: R8.

Product Name: Inverter.
Model: ACS550-01-368A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 250HP.
Typical motor power in 400 V at normal use: 200kw.
Typical motor power in 460 V at normal use: 300hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 368A.
Typical motor power in 400 V at heavy-duty use: 160KW.
Free-standing units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 302A.
Frame size: R8.

Product Name: Inverter.
Model: ACS550-01-602A-4.
3-phase supply voltage 380 to 480 V.
Free-standing units.
Typical motor power in 400 V at normal use: 315kw.
Frame size: R8.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 602A.
Typical motor power in 400 V at heavy-duty use: 280KW.
Typical motor power in 460 V at heavy-duty use: 450HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 515A.
Typical motor power in 460 V at normal use: 500hp.

Product Name: Inverter.
Model: ACS550-01-526A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 400HP.
Typical motor power in 400 V at normal use: 280kw.
Typical motor power in 460 V at normal use: 450hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 526A.
Typical motor power in 400 V at heavy-duty use: 250KW.
Free-standing units.
Continuous rms current. 50% overload is allowed forr ACS550-02-486A-4 one minute in ten minutes: 477A.
Frame size: R8.