Home >> Products >> ABB >> Inverter >> ACS550 Inverter
ABB Inverter ACS550-01-072A-4
Product Name: Inverter.
Model: ACS550-01-072A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 400 V at heavy-duty use: 30KW.
Typical motor power in 400 V at normal use: 37kw.
Typical motor power in 460 V at normal use: 50hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 72A.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 40HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 59A.
Frame size: R4.
ABB Inverter ACS550-01-087A-4
Product Name: Inverter.
Model: ACS550-01-087A-4.
Frame size: R4.
Wall-mounted units.
Typical motor power in 400 V at normal use: 45kw.
Typical motor power in 460 V at normal use: 60hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 87A.
Typical motor power in 400 V at heavy-duty use: 37KW.
Typical motor power in 460 V at heavy-duty use: 60HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 72A.
3-phase supply voltage 380 to 480 V.
ABB Inverter ACS550-01-125A-4
Product Name: Inverter.
Model: ACS550-01-125A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 55kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 96A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 125A.
Typical motor power in 400 V at heavy-duty use: 45KW.
Typical motor power in 460 V at heavy-duty use: 75HP.
Typical motor power in 460 V at normal use: 100hp.
Frame size: R5.
ABB Inverter ACS550-01-157A-4
Product Name: Inverter.
Model: ACS550-01-157A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 100HP.
Typical motor power in 460 V at normal use: 125hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 157A.
Typical motor power in 400 V at heavy-duty use: 55KW.
Typical motor power in 400 V at normal use: 75kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 125A.
Frame size: R6.
ABB Inverter ACS550-01-180A-4
Product Name: Inverter.
Model: ACS550-01-180A-4.
Typical motor power in 460 V at normal use: 150hp.
Wall-mounted units.
Typical motor power in 400 V at normal use: 90kw.
3-phase supply voltage 380 to 480 V.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 180A.
Typical motor power in 400 V at heavy-duty use: 75KW.
Typical motor power in 460 V at heavy-duty use: 125HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 156A.
Frame size: R6.
ABB Inverter ACS550-01-195A-4
Product Name: Inverter.
Model: ACS550-01-195A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 110kw.
Frame size: R6.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 205A.
Typical motor power in 400 V at heavy-duty use: 90KW.
Typical motor power in 460 V at heavy-duty use: 125HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 162A.
Typical motor power in 460 V at normal use: 150hp.
ABB Inverter ACS550-01-246A-4
Product Name: Inverter.
Model: ACS550-01-246A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 132kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 192A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 246A.
Typical motor power in 400 V at heavy-duty use: 110KW.
Typical motor power in 460 V at heavy-duty use: 150HP.
Typical motor power in 460 V at normal use: 200hp.
Frame size: R6.
ABB Inverter ACS550-01-290A-4
Product Name: Inverter.
Model: ACS550-01-290A-4.
Typical motor power in 400 V at heavy-duty use: 132KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 160kw.
Typical motor power in 460 V at normal use: 200hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 290A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 200HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 246A.
Frame size: R6.
ABB Inverter ACS550-02-368A-4
Product Name: Inverter.
Model: ACS550-01-368A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 250HP.
Typical motor power in 400 V at normal use: 200kw.
Typical motor power in 460 V at normal use: 300hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 368A.
Typical motor power in 400 V at heavy-duty use: 160KW.
Free-standing units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 302A.
Frame size: R8.
ABB Inverter ACS550-02-486A-4
Product Name: Inverter.
Model: ACS550-01-486A-4.
3-phase supply voltage 380 to 480 V.
Free-standing units.
Frame size: R8.
Typical motor power in 460 V at normal use: 400hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 486A.
Typical motor power in 400 V at heavy-duty use: 200KW.
Typical motor power in 460 V at heavy-duty use: 350HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 414A.
Typical motor power in 400 V at normal use: 250kw.
ABB Inverter ACS550-02-526A-4
Product Name: Inverter.
Model: ACS550-01-526A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 400HP.
Typical motor power in 400 V at normal use: 280kw.
Typical motor power in 460 V at normal use: 450hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 526A.
Typical motor power in 400 V at heavy-duty use: 250KW.
Free-standing units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 477A.
Frame size: R8.
ABB Inverter ACS550-02-602A-4
Product Name: Inverter.
Model: ACS550-01-602A-4.
3-phase supply voltage 380 to 480 V.
Free-standing units.
Typical motor power in 400 V at normal use: 315kw.
Frame size: R8.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 602A.
Typical motor power in 400 V at heavy-duty use: 280KW.
Typical motor power in 460 V at heavy-duty use: 450HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 515A.
Typical motor power in 460 V at normal use: 500hp.
25 Results 12/Page Page 2 of 3     << Previous 1 2 3 Next >>