Home >> Products >> ABB >> Inverter >> ACS550 Inverter >> ACS550-01-087A-4 ABB ACS550-01-087A-4

ACS550-01-087A-4 ABB ACS550-01-087A-4

Product Name: Inverter.
Model: ACS550-01-087A-4.
Frame ACS550-01-072A-4 size: R4.
Wall-mounted units.
Typical motor ACS550-01-072A-4 power in 400 V at normal use: 45kw.
Typical motor power in 460 V at normal use: 60hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 87A.
Typical motor power in 400 V at heavy-duty use: 37KW.
Typical motor power in 460 V at heavy-duty use: 60HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 72A.
3-phase supply voltage 380 to 480 V.
ABB ACS550-01-087A-4
Product Name: Inverter.
Model: ACS550-01-03A3-4.
3-phase supply voltage ABB ACS550-01-072A-4 380 to 480 V.
Wall-mounted units.
Frame size: R1.
Typical motor power in 460 V at normal use: 1.5hp.
Continuous ABB ACS550-01-072A-4 rms current. 10% overload is allowed for one minute in ten minutes: 3.3A.
Typical ABB ACS550-01-072A-4 motor power in 400 V at heavy-duty use: 0.75KW.
Typical motor power in 460 V at heavy-duty use: 1HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 2.4A.
Typical motor power in 400 V at normal use: 1.1kw.

Product Name: Inverter.
Model: ACS550-01-023A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 10HP.
Typical motor power in 400 V at normal use: 11kw.
Typical motor power in 460 V at normal use: 15hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 23A.
Typical motor power in 400 V at heavy-duty use: 7.5KW.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 15.4A.
Frame size: R2.

Product Name: Inverter.
Model: ACS550-01-012A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 5.5kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 8.8A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 11.9A.
Typical motor power in 400 V at heavy-duty use: 4KW.
Typical motor power in 460 V at heavy-duty use: 5.4HP.
Typical motor power in 460 V at normal use: 7.5hp.
Frame size: R1.

Product Name: Inverter.
Model: ACS550-01-045A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 22kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 38A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 45A.
Typical motor power in 400 V at heavy-duty use: 18.5KW.
Typical motor power in 460 V at heavy-duty use: 25HP.
Typical motor ppower ACS550-01-072A-4 in 460 V at normal use: 30hp.
Frame size: R3.





...More Related Model >>>>