Home >> Products >> ABB >> Inverter >> ACS550 Inverter >> ACS550-01-03A3-4 Typical motor power in 460 V at normal use 1.5hp. ABB ACS550-01-03A3-4 Inverter

ACS550-01-03A3-4 Typical motor power in 460 V at normal use 1.5hp. ABB ACS550-01-03A3-4 Inverter

Product Name: Inverter.
Model: ACS550-01-03A3-4.
3-phase ACS550-01-03A3-4 supply voltage 380 to 480 V.
Wall-mounted units.
Frame size: ACS550-01-03A3-4 R1.
Typical motor power in 460 V at normal use: 1.5hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 3.3A.
Typical motor power in 400 V at heavy-duty use: 0.75KW.
Typical motor power in 460 V at heavy-duty use: 1HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 2.4A.
Typical motor power in 400 V at normal use: 1.1kw.
ABB ACS550-01-03A3-4
Product Name: Inverter.
Model: ACS550-01-05A4-4.
3-phase supply voltage ABB ACS550-01-03A3-4 380 to 480 V.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 5.4A.
Typical ABB ACS550-01-03A3-4 motor power in 400 V at normal use: 2.2kw.
Typical motor power in 460 V at normal ABB ACS550-01-03A3-4 use: 3hp.
Wall-mounted units.
Typical motor power in 400 V at heavy-duty use: 1.5KW.
Typical motor power in 460 V at heavy-duty use: 2HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.1A.
Frame size: R1.

Product Name: Inverter.
Model: ACS550-01-06A9-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Frame size: R1.
Typical motor power in 460 V at normal use: 4hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 6.9A.
Typical motor power in 400 V at heavy-duty use: 2.2KW.
Typical motor power in 460 V at heavy-duty use: 3HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 5.4A.
Typical motor power in 400 V at normal use: 3kw.

Product Name: Inverter.
Model: ACS550-01-059A-4.
Typical motor power in 400 V at heavy-duty use: 22KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 30kw.
Typical motor power in 460 V at normal use: 40hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 59A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 30HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 45A.
Frame size: R4.

Product Name: Inverter.
Model: ACS550-01-015A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 7.5kw.
Typical motor power in 460 V at normal use: 10hp.
Frame size: R2.
Typical motor power in 400 V at heavy-duty use: 5.5KW.
Typical motor power in 460 V at heavy-duty use: 7.5HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 11.9A.
Continuous rms current. 10% overrload ACS550-01-03A3-4 is allowed for one minute in ten minutes: 15.4A.