Product Name: Inverter.
Model: ACS550-01-038A-4.
3-phase ACS550-01-038A-4 supply voltage 380 to 480 V.
Typical motor ACS550-01-038A-4 power in 400 V at heavy-duty use: 15KW.
Typical motor power in 400 V at normal use: 18.5kw.
Typical motor power in 460 V at normal use: 25hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 38A.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 20HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31A.
Frame size: R3.
ABB ACS550-01-038A-4
Product Name: Inverter.
Model: ACS550-01-045A-4.
3-phase supply voltage ABB ACS550-01-038A-4 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 22kw.
Continuous rms ABB ACS550-01-038A-4 current. 50% overload is allowed for one minute in ten minutes: 38A.
Continuous rms ABB ACS550-01-038A-4 current. 10% overload is allowed for one minute in ten minutes: 45A.
Typical motor power in 400 V at heavy-duty use: 18.5KW.
Typical motor power in 460 V at heavy-duty use: 25HP.
Typical motor power in 460 V at normal use: 30hp.
Frame size: R3.

Product Name: Inverter.
Model: ACS550-01-015A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 7.5kw.
Typical motor power in 460 V at normal use: 10hp.
Frame size: R2.
Typical motor power in 400 V at heavy-duty use: 5.5KW.
Typical motor power in 460 V at heavy-duty use: 7.5HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 11.9A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 15.4A.

Product Name: Inverter.
Model: ACS550-01-023A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 10HP.
Typical motor power in 400 V at normal use: 11kw.
Typical motor power in 460 V at normal use: 15hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 23A.
Typical motor power in 400 V at heavy-duty use: 7.5KW.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 15.4A.
Frame size: R2.

Product Name: Inverter.
Model: ACS550-01-04A1-4.
Typical motor power in 400 V at heavy-duty use: 1.1KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 1.5kw.
Typical motor power in 460 V at normal use: 2hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 4.1A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 1.5HP.
Continuous rms current. 50% overload is allowed forr ACS550-01-038A-4 one minute in ten minutes: 3.3A.
Frame size: R1.