Home >> Products >> ABB
ABB Inverter ACS355-03X-08A8-4
Product Name: Inverter.
Model: ACS355-03X-08A8-4.
3-phase AC supply, 380 to 480 V.
This code states the factory installed SW variants to the drive.
Typical motor power in 460 V at normal use: 5.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 8.8A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 400 V at normal use: 4.0kw.
ABB Inverter ACS355-03X-12A5-4
Product Name: Inverter.
Model: ACS355-03X-12A5-4.
3-phase AC supply, 380 to 480 V.
This code states the factory installed SW variants to the drive.
Typical motor power in 460 V at normal use: 7.5hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 12.5A.
Frame size: R3.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 400 V at normal use: 5.5kw.
ABB Inverter ACS355-03X-15A6-4
Product Name: Inverter.
Model: ACS355-03X-15A6-4.
This code states the factory installed SW variants to the drive.
Typical motor power in 400 V at normal use: 7.5kw.
Typical motor power in 460 V at normal use: 10.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 15.6A.
Frame size: R3.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
3-phase AC supply, 380 to 480 V.
ABB Inverter ACS355-03X-23A1-4
Product Name: Inverter.
Model: ACS355-03X-23A1-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 11.0kw.
Frame size: R3.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 23.1A.
Typical motor power in 460 V at normal use: 15.0hp.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-31A0-4
Product Name: Inverter.
Model: ACS355-03X-31A0-4.
This code states the factory installed SW variants to the drive.
Typical motor power in 400 V at normal use: 15.0kw.
Typical motor power in 460 V at normal use: 20.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31.0A.
Frame size: R4.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
3-phase AC supply, 380 to 480 V.
ABB Inverter ACS355-03X-38A0-4
Product Name: Inverter.
Model: ACS355-03X-38A0-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 18.5kw.
Current rating represents the rated continuous drive output current inside the drive specification.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 38.0A.
Frame size: R4.
Typical motor power in 460 V at normal use: 25.0hp.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-44A0-4
Product Name: Inverter.
Model: ACS355-03X-44A0-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 22.0kw.
Typical motor power in 460 V at normal use: 30.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 44.0A.
This code states the factory installed SW variants to the drive.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Frame size: R4.
ABB Inverter ACS800-01-0001-2
Product Name: Inverter.
Model: ACS800-01-0001-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Frame size: R2.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
Typical motor power in no-overload use: 1.1KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.7A.
Typical motor power in light-overload use: 0.75Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
Typical motor power in heavy-duty use: 0.55KW.
Rated current available continuously without overloadability at 40 °C: 5.1A
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0002-2
Product Name: Inverter.
Model: ACS800-01-0002-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 6.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Frame size: R2.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 6.0A.
Typical motor power in light-overload use: 1.1Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 4.3A.
Typical motor power in heavy-duty use: 0.75KW.
Typical motor power in no-overload use: 1.5KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0003-2
Product Name: Inverter.
Model: ACS800-01-0003-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 8.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 1.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 1.5Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 1.1KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0004-2
Product Name: Inverter.
Model: ACS800-01-0004-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 10.9A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Typical motor power in light-overload use: 2.2Kw.
Typical motor power in no-overload use: 2.2KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10.2A.
Phd: 13.8A.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.5A.
Typical motor power in heavy-duty use: 1.5KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0005-2
Product Name: Inverter.
Model: ACS800-01-0005-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 13.9A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 17.6A.
Typical motor power in no-overload use: 3KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 9.3A.
Typical motor power in heavy-duty use: 2.2KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 12.7A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
117 Results 12/Page Page 5 of 10     << Previous 1 2 3 4 5 6 7 8 9 10 Next >>