Home >> Products >> ABB >> ABB Inverter
ABB Inverter ACS355-03X-13A3-2
Product Name: Inverter.
Model: ACS355-03X-13A3-2.
3-phase AC supply, 200 to 240 V.
Typical motor power in 400 V at normal use: 3.0kw.
Typical motor power in 460 V at normal use: 3.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 13.3A.
This code states the factory installed SW variants to the drive.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Frame size: R2.
ABB Inverter ACS355-03X-17A6-2
Product Name: Inverter.
Model: ACS355-03X-17A6-2.
3-phase AC supply, 200 to 240 V.
Typical motor power in 400 V at normal use: 4.0kw.
This code states the factory installed SW variants to the drive.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 17.6A.
Frame size: R2.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 460 V at normal use: 5.0hp.
ABB Inverter ACS355-03X-24A4-2
Product Name: Inverter.
Model: ACS355-03X-24A4-2.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 400 V at normal use: 5.5kw.
Typical motor power in 460 V at normal use: 7.5hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 24.4A.
Frame size: R3.
Current rating represents the rated continuous drive output current inside the drive specification.
3-phase AC supply, 200 to 240 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-31A0-2
Product Name: Inverter.
Model: ACS355-03X-31A0-2.
3-phase AC supply, 200 to 240 V.
Typical motor power in 400 V at normal use: 7.5kw.
This code states the factory installed SW variants to the drive.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31.0A.
Frame size: R4.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 460 V at normal use: 10.0hp.
ABB Inverter ACS355-03X-46A2-2
Product Name: Inverter.
Model: ACS355-03X-46A2-2.
3-phase AC supply, 200 to 240 V.
Frame size: R4.
Typical motor power in 460 V at normal use: 15.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 46.2A.
Typical motor power in 400 V at normal use: 11.0kw.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-01A2-4
Product Name: Inverter.
Model: ACS355-03X-01A2-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 0.37kw.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 1.2A.
Frame size: R0.
Current rating represents the rated continuous drive output current inside the drive specification.
Typical motor power in 460 V at normal use: 0.5hp.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-01A9-4
Product Name: Inverter.
Model: ACS355-03X-01A9-4.
Typical motor power in 460 V at normal use: 0.75hp.
Typical motor power in 400 V at normal use: 0.55kw.
3-phase AC supply, 380 to 480 V.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 1.9A.
Frame size: R0.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-02A4-4
Product Name: Inverter.
Model: ACS355-03X-02A4-4.
3-phase AC supply, 380 to 480 V.
This code states the factory installed SW variants to the drive.
Typical motor power in 460 V at normal use: 1.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 2.4A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 400 V at normal use: 0.75kw.
ABB Inverter ACS355-03X-03A3-4
Product Name: Inverter.
Model: ACS355-03X-03A3-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 1.1kw.
This code states the factory installed SW variants to the drive.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 3.3A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 460 V at normal use: 1.5hp.
ABB Inverter ACS355-03X-04A1-4
Product Name: Inverter.
Model: ACS355-03X-04A1-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 1.5kw.
This code states the factory installed SW variants to the drive.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.1A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 460 V at normal use: 2.0hp.
ABB Inverter ACS355-03X-05A6-4
Product Name: Inverter.
Model: ACS355-03X-05A6-4.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 400 V at normal use: 2.2kw.
Typical motor power in 460 V at normal use: 3.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 5.6A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
3-phase AC supply, 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-07A3-4
Product Name: Inverter.
Model: ACS355-03X-07A3-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 3.0kw.
Current rating represents the rated continuous drive output current inside the drive specification.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 7.3A.
Frame size: R1.
Typical motor power in 460 V at normal use: 3.0hp.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
117 Results 12/Page Page 4 of 10     << Previous 1 2 3 4 5 6 7 8 9 10 Next >>