Home >> Products >> ABB >> Inverter >> ACS800 Inverter
ABB Inverter ACS800-01-0165-5
Product Name: Inverter.
Model: ACS800-01-0165-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 225A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
Typical motor power in no-overload use: 132KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 220A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 163A.
Typical motor power in heavy-duty use: 110KW.
Frame size: R6.
Typical motor power in light-overload use: 132Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0205-5
Product Name: Inverter.
Model: ACS800-01-0205-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 260A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 215A.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 254A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0255-5
Product Name: Inverter.
Model: ACS800-01-0255-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 290A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 351A.
Typical motor power in no-overload use: 200KW
Frame size: R6.
Typical motor power in light-overload use: 200Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 234A.
Typical motor power in heavy-duty use: 160KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 285A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0011-7
Product Name: Inverter.
Model: ACS800-01-0011-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 13A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 14A.
Typical motor power in no-overload use: 11KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 11.5A.
Frame size: R4.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 8.5A.
Typical motor power in heavy-duty use: 5.5KW.
Typical motor power in light-overload use: 7.5Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0016-7
Product Name: Inverter.
Model: ACS800-01-0016-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 17A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 19A.
Typical motor power in no-overload use: 15KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in light-overload use: 11Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 11A.
Typical motor power in heavy-duty use: 7.5KW.
Frame size: R4.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 15A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0020-7
Product Name: Inverter.
Model: ACS800-01-0020-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 22A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 28A.
Typical motor power in no-overload use: 18.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 20A.
Typical motor power in light-overload use: 15Kw.
Frame size: R4.
Typical motor power in heavy-duty use: 11KW.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 15A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0025-7
Product Name: Inverter.
Model: ACS800-01-0025-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 38A.
Typical motor power in no-overload use: 22KW
Frame size: R4.
Typical motor power in light-overload use: 18.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
Typical motor power in heavy-duty use: 15KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 23A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0030-7

Product Name: Inverter.
Model: ACS800-01-0030-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 33A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 44A.
Typical motor power in no-overload use: 30KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 30A.
Frame size: R4.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 22A.
Typical motor power in heavy-duty use: 18.5KW.
Typical motor power in light-overload use: 22Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

ABB Inverter ACS800-01-0040-7
Product Name: Inverter.
Model: ACS800-01-0040-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 36A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 54A.
Typical motor power in no-overload use: 30KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in light-overload use: 30Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 27A.
Typical motor power in heavy-duty use: 22KW.
Frame size: R4.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 34A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0070-7

Product Name: Inverter.
Model: ACS800-01-0070-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 79A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 104A.
Typical motor power in no-overload use: 75KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 73A.
Typical motor power in light-overload use: 55Kw.
Frame size: R6.
Typical motor power in heavy-duty use: 45KW.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 54A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

ABB Inverter ACS800-01-0100-7
Product Name: Inverter.
Model: ACS800-01-0100-7.
Frame size: R6.
Rated current available continuously without overloadability at 40 °C: 93A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 124A.
Typical motor power in no-overload use: 90KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 86A.
Typical motor power in light-overload use: 75Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 62A.
Typical motor power in heavy-duty use: 55KW.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0120-7
Product Name: Inverter.
Model: ACS800-01-0120-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 113A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 172A.
Typical motor power in no-overload use: 110KW
Frame size: R6.
Typical motor power in light-overload use: 90Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 86A.
Typical motor power in heavy-duty use: 75KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 108A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
62 Results 12/Page Page 5 of 6     << Previous 1 2 3 4 5 6 Next >>