Home >> Products >> 97
Mennekes Wall mounted inlet 1975
Product Name:Wall mounted inlet
Part No.1975.
Ampere :32A.
Poles:3P.
Voltage:20-25V.
Hertz:50-60 Hz.
Earth position:0 h.
Connection technology:Screw terminals.
Contact:standard.
Protection type:IP44.
screw terminals.
external fixing.
one cable entry at top and one blind cable entry (can be cut out) at the back side.
Mennekes Cepex flush mounted receptacle SCHUKO 4979
Product Name:Cepex panel mounted receptacle SCHUKO?
Part No.:4979.
Ampere :16A.
Poles:2p.
Voltage:230V.
Earth position:0h.
Hertz:50-60 Hz.
Shutter:no.
Protection type:IP44.
alpine white or pearl white.
screw terminals.
suitable for installation in cable ducts and columns.
meeting DIN 18032 standards for ball rebound.
Mennekes Cepex flush mounted receptacle SCHUKO 4971
Product Name:Cepex panel mounted receptacle SCHUKO?
Part No.:4971.
Ampere :16A.
Poles:2p.
Voltage:230V.
Earth position:0h.
Hertz:50-60 Hz.
Shutter:no.
Protection type:IP44.
alpine white or pearl white.
screw terminals.
suitable for installation in cable ducts and columns.
meeting DIN 18032 standards for ball rebound.
Mennekes Receptacle combination 97990
Product Name:Receptacle combination
Part No.:97990.
Ampere:16A.
Poles:5p.
Voltage:400V.
Earth position :6h.
Hertz50-60 Hz.
Protection type:IP44.
screw terminals.
CEE and receptacle SCHUKO? in one enclosure.
fitted with Neozed D01, 1p.
Mennekes Connector PowerTOP 3970
Product Name:Connector PowerTOP?
Part No.:3970.
Ampere:32A.
Poles:4p
Voltage:400V.
Earth position:6h.
Hertz 50-60Hz.
Connection technology:screw terminals.
Contact:highly heat resistant contact carrier.
Protection type IP44.
screw terminals.
with highly heat resistant contact carrier.
cable gland and external cable grip.
Mennekes Connector PowerTOP 3974
Product Name:Connector PowerTOP?
Part No.:3974.
Ampere:32A.
Poles:5p
Voltage:110V.
Earth position:4h.
Hertz 50-60Hz.
Connection technology:screw terminals.
Contact:highly heat resistant contact carrier.
Protection type IP44.
screw terminals.
with highly heat resistant contact carrier.
cable gland and external cable grip.
ABB Inverter ACS800-01-0060-5
Product Name: Inverter.
Model: ACS800-01-0060-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 79A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 112A.
Typical motor power in no-overload use: 45KW
Frame size: R5.
Typical motor power in light-overload use: 45Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 60A.
Typical motor power in heavy-duty use: 37KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 75A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0016-5
Product Name: Inverter.
Model: ACS800-01-0016-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 19A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 24A.
Frame size: R3.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 18A.
Typical motor power in light-overload use: 11Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 13A.
Typical motor power in heavy-duty use: 7.5KW.
Typical motor power in no-overload use: 11KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0060-3
Product Name: Inverter.
Model: ACS800-01-0060-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 103A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
Typical motor power in no-overload use: 55KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 94A.
Typical motor power in light-overload use: 45Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 37KW.
143 Results 12/Page Page 9 of 12     [First Page] << Previous 5 6 7 8 9 10 11 12 Next >>