Mitsubishi Inverter FR-F740-22K
Product Name: Inverter.
Model: FR-F740-22K.
22KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 22 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 41 kVA
Cooling system: Forced air cooling.
Approx. mass: 13 Kg.
Mitsubishi Inverter FR-F740-2.2K
Product Name: Inverter.
Model: FR-F740-2.2K.
2.2KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 2.2 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 5.5 kVA
Cooling system: Forced air cooling.
Approx. mass: 3.5 Kg.
Proface HMI AGP3560-T1-AF-M
Product Name: HMI(Multi-Media).
Model: AGP3560-T1-AF-M.
Display Type and Size: TFT Color LCD(10.4in).
Graphic Display Resolution: 800*600 pixels(SVGA).
Display Colors: 65, 536 Colors(no blink)/16, 384 Colors(blink).
Display Area: W211.2 x H158.4 mm [W8.31 x H6.24 in].
Input Voltage: 100-240 VAC.
Backlight: CCFL.
CF Card: 1 slot/Type II.
Serial Ports(COM1): RS-232C/422/485.
Serial Ports(COM2): RS-422/485.
Ethernet: Yes.
Programming Memory: 10mb flash EPROM.
Touch Screen: Resistive Film(analog).
suffix denotes product is conformal coated.
Proface HMI GP2500-LG41-24V
Product Name: HMI(Progammable operator interfaces).
Model: GP2500-SC41-24V.
Type: 10.4-inch 640 × 480 Monochrome LCD.
Display Colors: Black and White (2 Shades)/ Black and White (8 Shades)(software control).
Backlight: CCFL (Service life: 50, 000 hrs. at 24hr. operation).
Resolution: 640 × 480 pixels.
Nominal Display Area (mm): 211.2(W) × 158.4(H).
Data Backup Memory: 128KB - uses lithium battery.
Contrast Control: 8 levels of adjustment available via touch panel.
Font Sizes: Width can be expanded 1 to 8 times.Height can be expanded 1/2*3, 1 to 8 times.
Rated Voltage: DC24V.
Application Memory: FLASH EPROM 4MB.
Brightness Control: 4 levels of adjustment available via touch panel.
ABB Inverter ACS550-01-05A4-4
Product Name: Inverter.
Model: ACS550-01-05A4-4.
3-phase supply voltage 380 to 480 V.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 5.4A.
Typical motor power in 400 V at normal use: 2.2kw.
Typical motor power in 460 V at normal use: 3hp.
Wall-mounted units.
Typical motor power in 400 V at heavy-duty use: 1.5KW.
Typical motor power in 460 V at heavy-duty use: 2HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.1A.
Frame size: R1.
ABB Inverter ACS550-02-486A-4
Product Name: Inverter.
Model: ACS550-01-486A-4.
3-phase supply voltage 380 to 480 V.
Free-standing units.
Frame size: R8.
Typical motor power in 460 V at normal use: 400hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 486A.
Typical motor power in 400 V at heavy-duty use: 200KW.
Typical motor power in 460 V at heavy-duty use: 350HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 414A.
Typical motor power in 400 V at normal use: 250kw.
ABB Inverter ACS355-03X-12A5-4
Product Name: Inverter.
Model: ACS355-03X-12A5-4.
3-phase AC supply, 380 to 480 V.
This code states the factory installed SW variants to the drive.
Typical motor power in 460 V at normal use: 7.5hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 12.5A.
Frame size: R3.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 400 V at normal use: 5.5kw.
ABB Inverter ACS800-01-0040-5
Product Name: Inverter.
Model: ACS800-01-0040-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 48A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 72A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 44A.
Typical motor power in light-overload use: 30Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 36A.
Typical motor power in heavy-duty use: 22KW.
Frame size: R4.
Typical motor power in no-overload use: 30KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0205-7
Product Name: Inverter.
Model: ACS800-01-0205-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 190A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 245A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 180A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 147A.