Mitsubishi INVerter FR-A740-355K
Product Name: INVerter.
Model: FR-A740-355K.
355 KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 355 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 521 kVA
Cooling system: Forced air cooling.
Approx. mass: 260 Kg.
Mitsubishi INVerter FR-A740-315K
Product Name: INVerter.
Model: FR-A740-315K.
315 KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 315 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 465 kVA
Cooling system: Forced air cooling.
Approx. mass: 260 Kg.
Mitsubishi INVerter FR-F740-S315K
Product Name: INVerter.
Model: FR-F740-S315K.
315 KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 315 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 464 kVA
Cooling system: Forced air cooling.
Approx. mass: 175 Kg.
Mitsubishi INVerter FR-F740-22K
Product Name: INVerter.
Model: FR-F740-22K.
22KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 22 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 41 kVA
Cooling system: Forced air cooling.
Approx. mass: 13 Kg.
Mitsubishi INVerter FR-F740-2.2K
Product Name: INVerter.
Model: FR-F740-2.2K.
2.2KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 2.2 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 5.5 kVA
Cooling system: Forced air cooling.
Approx. mass: 3.5 Kg.
Proface Bus CoNVersion Unit PSM-CONV00
This Unit is designed to be attached to the rear face of a GLC2000 Series unit. Then, either a GP77R Series or a GLC100 Series middle-sized expansion unit is attached to the outside face of this coNVerter.
ABB INVerter ACS550-01-05A4-4
Product Name: INVerter.
Model: ACS550-01-05A4-4.
3-phase supply voltage 380 to 480 V.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 5.4A.
Typical motor power in 400 V at normal use: 2.2kw.
Typical motor power in 460 V at normal use: 3hp.
Wall-mounted units.
Typical motor power in 400 V at heavy-duty use: 1.5KW.
Typical motor power in 460 V at heavy-duty use: 2HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.1A.
Frame size: R1.
ABB INVerter ACS550-01-023A-4
Product Name: INVerter.
Model: ACS550-01-023A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 10HP.
Typical motor power in 400 V at normal use: 11kw.
Typical motor power in 460 V at normal use: 15hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 23A.
Typical motor power in 400 V at heavy-duty use: 7.5KW.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 15.4A.
Frame size: R2.
ABB INVerter ACS550-01-125A-4
Product Name: INVerter.
Model: ACS550-01-125A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 55kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 96A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 125A.
Typical motor power in 400 V at heavy-duty use: 45KW.
Typical motor power in 460 V at heavy-duty use: 75HP.
Typical motor power in 460 V at normal use: 100hp.
Frame size: R5.
ABB INVerter ACS550-01-180A-4
Product Name: INVerter.
Model: ACS550-01-180A-4.
Typical motor power in 460 V at normal use: 150hp.
Wall-mounted units.
Typical motor power in 400 V at normal use: 90kw.
3-phase supply voltage 380 to 480 V.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 180A.
Typical motor power in 400 V at heavy-duty use: 75KW.
Typical motor power in 460 V at heavy-duty use: 125HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 156A.
Frame size: R6.
ABB INVerter ACS550-02-486A-4
Product Name: INVerter.
Model: ACS550-01-486A-4.
3-phase supply voltage 380 to 480 V.
Free-standing units.
Frame size: R8.
Typical motor power in 460 V at normal use: 400hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 486A.
Typical motor power in 400 V at heavy-duty use: 200KW.
Typical motor power in 460 V at heavy-duty use: 350HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 414A.
Typical motor power in 400 V at normal use: 250kw.
886 Results 12/Page Page 25 of 74     [First Page] << Previous 21 22 23 24 25 26 27 28 29 30 Next >> [Last Page]