Home >> Products >> 37
Mitsubishi Temperature input Module A1S62RD4N
Product: Temperature input Module.
Model: A1S62RD4N.
Outline: 2 channels, 4-wire type platinum RTD (Pt100 [JIS C1604-1997, IEC 751-am2, JIS C1604-1989, DIN 43760-1980], JPt100 [JIS C1604-1981]), conversion speed: 40 ms/channel, 20-point terminal block.
Mitsubishi Base unit A37RHB
Model: A37RHB.
Redundant power supply base unit for.
7 slots on one side.
Q4AR for redundant system.
Size: 250(H)×497(W)×29(D)mm.
Weight: 2.2kg.
Mitsubishi MELSECNET/10 network module AJ71QLP21S
Model: AJ71QLP21S.
Between net MELSECNET/10 PC, / normal station management.
MELSECNET/10 Remote I / O network, remote master station.
Optical loop system.
Connection cable: SI / QSI / H-H broadband PCF /-optic PCF.
Transmission format: double loop.
Function with an external power source..
Size: 250(H)×37.5(W)×111(D)mm.
Weight: 0.39kg.
ABB Inverter ACS355-03X-02A4-2
Product Name: Inverter.
Model: ACS355-03X-02A4-2.
3-phase AC supply, 200 to 240 V.
Typical motor power in 400 V at normal use: 0.37kw.
Current rating represents the rated continuous drive output current inside the drive specification.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 2.4A.
Frame size: R0.
Typical motor power in 460 V at normal use: 0.5hp.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS800-01-0050-2
Product Name: Inverter.
Model: ACS800-01-0050-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 141A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 164A.
Typical motor power in no-overload use: 37KW
Frame size: R6.
Typical motor power in light-overload use: 37Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 97A.
Typical motor power in heavy-duty use: 30KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 132A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0070-2
Product Name: Inverter.
Model: ACS800-01-0070-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Frame size: R6.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 282A.
Typical motor power in no-overload use: 55KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 184A.
Typical motor power in light-overload use: 55Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 141A.
Typical motor power in heavy-duty use: 37KW.
Rated current available continuously without overloadability at 40 °C: 202A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0060-3
Product Name: Inverter.
Model: ACS800-01-0060-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 103A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
Typical motor power in no-overload use: 55KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 94A.
Typical motor power in light-overload use: 45Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 37KW.
ABB Inverter ACS800-01-0060-5
Product Name: Inverter.
Model: ACS800-01-0060-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 79A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 112A.
Typical motor power in no-overload use: 45KW
Frame size: R5.
Typical motor power in light-overload use: 45Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 60A.
Typical motor power in heavy-duty use: 37KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 75A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.