Home >> Products >> NV
Mitsubishi INVerter FR-A840-02160-2-60
Product Name: INVerter.
Model: FR-A840-02160-2-60.
75KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity(SLD): 110 kW.
Rated input AC voltage/frequency: Three-phase 380 to 500 V 50 Hz/60 Hz.
Cooling system: Forced air cooling.
Approx. mass: 52 Kg.
Mitsubishi INVerter FR-A740-450K
Product Name: INVerter.
Model: FR-A740-450K.
450 KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 450 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 660 kVA
Cooling system: Forced air cooling.
Approx. mass: 370 Kg.
Mitsubishi INVerter FR-F740-S400K
Product Name: INVerter.
Model: FR-F740-S400K.
400 KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 400 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 586 kVA
Cooling system: Forced air cooling.
Approx. mass: 260 Kg.
ABB INVerter ACS550-01-012A-4
Product Name: INVerter.
Model: ACS550-01-012A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 5.5kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 8.8A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 11.9A.
Typical motor power in 400 V at heavy-duty use: 4KW.
Typical motor power in 460 V at heavy-duty use: 5.4HP.
Typical motor power in 460 V at normal use: 7.5hp.
Frame size: R1.
ABB INVerter ACS550-01-031A-4
Product Name: INVerter.
Model: ACS550-01-031A-4.
Frame size: R3.
Wall-mounted units.
Typical motor power in 400 V at normal use: 15kw.
Typical motor power in 460 V at normal use: 20hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 31A.
Typical motor power in 400 V at heavy-duty use: 11KW.
Typical motor power in 460 V at heavy-duty use: 15HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 23A.
3-phase supply voltage 380 to 480 V.
ABB INVerter ACS550-01-045A-4
Product Name: INVerter.
Model: ACS550-01-045A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 22kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 38A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 45A.
Typical motor power in 400 V at heavy-duty use: 18.5KW.
Typical motor power in 460 V at heavy-duty use: 25HP.
Typical motor power in 460 V at normal use: 30hp.
Frame size: R3.
ABB INVerter ACS550-01-087A-4
Product Name: INVerter.
Model: ACS550-01-087A-4.
Frame size: R4.
Wall-mounted units.
Typical motor power in 400 V at normal use: 45kw.
Typical motor power in 460 V at normal use: 60hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 87A.
Typical motor power in 400 V at heavy-duty use: 37KW.
Typical motor power in 460 V at heavy-duty use: 60HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 72A.
3-phase supply voltage 380 to 480 V.
ABB INVerter ACS355-01X-04A7-2
Product Name: INVerter.
Model: ACS355-01X-04A7-2.
Frame size: R1.
Typical motor power in 400 V at normal use: 0.75kw.
Typical motor power in 460 V at normal use: 1.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 4.7A.
1-phase AC supply, 200 to 240 V.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB INVerter ACS355-03X-15A6-4
Product Name: INVerter.
Model: ACS355-03X-15A6-4.
This code states the factory installed SW variants to the drive.
Typical motor power in 400 V at normal use: 7.5kw.
Typical motor power in 460 V at normal use: 10.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 15.6A.
Frame size: R3.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
3-phase AC supply, 380 to 480 V.
ABB INVerter ACS800-01-0205-5
Product Name: INVerter.
Model: ACS800-01-0205-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 260A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 215A.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 254A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
886 Results 12/Page Page 20 of 74     [First Page] << Previous 16 17 18 19 20 21 22 23 24 25 Next >> [Last Page]