Home >> Products >> 250
OMRON Relay Output Module C200H-OC223
Model: C200H-OC223.
No. of points: 5 pts.
Specifications: 2A, 250VAC/24VDC(For resistive loads).
Mitsubishi Triac Output module AY22
Model: AY22.
Triac outputs: 16 points.AC100 ~ 240V, 2A / 1 Point, 3.3A / 1 common.
Response time: 1ms +0.5 cycles.
8 points per common.
20-point terminal block.
Size: 250(H)×37.5(W)×121(D)mm.
Weight: 0.71kg.
Mitsubishi Transistor Output module AY51
Model: AY51.
Transistor outputs: 32 points.DC12/24V, 0.5A / 1 Point, 4A / 1 common.
Response time: 2ms.
16 points per common.
Sinking.
38-point terminal block.
Size: 250(H)×37.5(W)×131(D)mm.
Weight: 0.53kg.
Mitsubishi Ethernet interface module AJ71QE71N-B2
Model: AJ71QE71N-B2.
Interface: 10BASE2.
Size: 250(H)×37.5(W)×106(D)mm.
Weight: 0.35kg.
Mitsubishi Intelligent Communications Module AD51-S3
Model: AD51-S3.
Basic program execution unit
Programming language: GPC-BASIC (interpreter), number of tasks: 8
RS-232: 2-Channel, RS-422: 2 Channels.
Size: 250(H)×76(W)×113.5(D)mm.
Weight: 1.1kg.
Mitsubishimaster local ModuleAJ61QBT11
Model: AJ61QBT11.
CC-Link system master local unit.
CC-Link, station / local station master.
Size: 250(H)×37.5(W)×129.1(D)mm.
Weight: 0.40kg.
ABB Inverter ACS550-02-486A-4
Product Name: Inverter.
Model: ACS550-01-486A-4.
3-phase supply voltage 380 to 480 V.
Free-standing units.
Frame size: R8.
Typical motor power in 460 V at normal use: 400hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 486A.
Typical motor power in 400 V at heavy-duty use: 200KW.
Typical motor power in 460 V at heavy-duty use: 350HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 414A.
Typical motor power in 400 V at normal use: 250kw.
ABB Inverter ACS550-02-526A-4
Product Name: Inverter.
Model: ACS550-01-526A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 400HP.
Typical motor power in 400 V at normal use: 280kw.
Typical motor power in 460 V at normal use: 450hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 526A.
Typical motor power in 400 V at heavy-duty use: 250KW.
Free-standing units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 477A.
Frame size: R8.
Proface MELSECNET/10 Unit(Optical loop type) GP070-MNL11
for GP-260x/ 250x Series * Bus Conversion Unit (PSL-CONV00) is required.
ABB Inverter ACS550-02-368A-4
Product Name: Inverter.
Model: ACS550-01-368A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 250HP.
Typical motor power in 400 V at normal use: 200kw.
Typical motor power in 460 V at normal use: 300hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 368A.
Typical motor power in 400 V at heavy-duty use: 160KW.
Free-standing units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 302A.
Frame size: R8.
400 Results 12/Page Page 19 of 34     [First Page] << Previous 15 16 17 18 19 20 21 22 23 24 Next >> [Last Page]