Home >> Products >> ABB >> Inverter >> ACS800 Inverter >> ACS800-01-0020-5 ABB ACS800-01-0020-5 Inverter

ACS800-01-0020-5 ABB ACS800-01-0020-5 Inverter

Product Name: Inverter.
Model: ACS800-01-0020-5.
UN ACS800-01-0020-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0020-5 nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 32A.
Typical motor power in no-overload use: 15KW
Frame size: R3.
Typical motor power in light-overload use: 15Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 18A.
Typical motor power in heavy-duty use: 11KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 23A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB ACS800-01-0020-5
Product Name: Inverter.
Model: ACS800-01-0020-2.
Frame ABB ACS800-01-0020-5 size: R4.
Rated current available continuously without ABB ACS800-01-0020-5 overloadability at 40 掳C: 55A
Maximum output current. Available for 10 s at start, ABB ACS800-01-0020-5 otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 72A.
Typical motor power in no-overload use: 15KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 50A.
Typical motor power in light-overload use: 15Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 37A.
Typical motor power in heavy-duty use: 7.5KW.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

Product Name: Inverter.
Model: ACS800-01-0020-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 掳C: 22A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 28A.
Typical motor power in no-overload use: 18.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 20A.
Typical motor power in light-overload use: 15Kw.
Frame size: R4.
Typical motor power in heavy-duty use: 11KW.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 15A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

Product Name: Inverter.
Model: ACS800-01-0020-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 掳C: 34A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 46A.
Typical motor power in no-overload use: 15KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 15Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 23A.
Typical motor power in heavy-duty use: 11KW.
Frame size: R3.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 31A.
In -0205-3 and -0255-5 uunits, ACS800-01-0020-5 H1 is 994 mm, depth 424 mm and weight is 80 kg.





...More Related Model >>>>

Related Download
Related Models