Home >> Products >> ABB >> Inverter >> ACS800 Inverter >> ACS800-01-0009-5 ABB ACS800-01-0009-5 Inverter

ACS800-01-0009-5 ABB ACS800-01-0009-5 Inverter

Product Name: Inverter.
Model: ACS800-01-0009-5.
UN ACS800-01-0009-5 = 500 V (Range 380 to 500 V). The power ratings are valid at ACS800-01-0009-5 nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 10.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 13.8A.
Typical motor power in no-overload use: 5.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10A.
Typical motor power in light-overload use: 5.5Kw.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Typical motor power in heavy-duty use: 4KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.56A.
ABB ACS800-01-0009-5
Product Name: Inverter.
Model: ACS800-01-0001-2.
UN ABB ACS800-01-0009-5 = 230 V (Range 208 to 240 V). The power ratings are valid ABB ACS800-01-0009-5 at nominal voltage 230 V.
Frame size: R2.
Maximum output current. Available for ABB ACS800-01-0009-5 10 s at start, otherwise as long as allowed by drive temperature. Inverter Note: max. motor shaft power is 150% Phd: 6.5A.
Typical motor power in no-overload use: 1.1KW
Continuous Inverter current allowing 110% IN for 1 min / 5 min at 40 掳C: 4.7A.
Typical motor power in Inverter light-overload use: 0.75Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 3.4A.
Typical motor power in heavy-duty use: 0.55KW.
Rated current available continuously without overloadability at 40 掳C: 5.1A
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

Product Name: Inverter.
Model: ACS800-01-0002-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 掳C: 6.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Frame size: R2.
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 6.0A.
Typical motor power in light-overload use: 1.1Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 4.3A.
Typical motor power in heavy-duty use: 0.75KW.
Typical motor power in no-overload use: 1.5KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

Product Name: Inverter.
Model: ACS800-01-0004-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 掳C: 10.9A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Typical motor power in light-overload use: 2.2Kw.
Typical motor power in no-overload use: 2.2KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 10.2A.
Phd: 13.8A.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 7.5A.
Typical motor power in heavy-duty use: 1.5KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.

Product Name: Inverter.
Model: ACS800-01-0003-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 掳C: 8.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 1.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 掳C: 7.7A.
Typical motor power in light-overload use: 1.5Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 1.1KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 掳C: 5.7A.
In -0205-3 and -0255-5 uunits, ABB ACS800-01-0009-5 H1 is 994 mm, depth 424 mm and weight is 80 kg.





...More Related Model >>>>

Related Download
Related Models