Home >> Products >> 77
ABB Inverter ACS800-01-0140-5
Product Name: Inverter.
Model: ACS800-01-0140-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 180A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 282A.
Frame size: R6.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 163A.
Typical motor power in light-overload use: 110Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 141A.
Typical motor power in heavy-duty use: 90KW.
Typical motor power in no-overload use: 110KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0025-7
Product Name: Inverter.
Model: ACS800-01-0025-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 38A.
Typical motor power in no-overload use: 22KW
Frame size: R4.
Typical motor power in light-overload use: 18.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
Typical motor power in heavy-duty use: 15KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 23A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0005-2
Product Name: Inverter.
Model: ACS800-01-0005-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 13.9A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 17.6A.
Typical motor power in no-overload use: 3KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 9.3A.
Typical motor power in heavy-duty use: 2.2KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 12.7A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0005-3
Product Name: Inverter.
Model: ACS800-01-0005-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 8.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 3KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
Typical motor power in heavy-duty use: 2.2KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0006-3
Product Name: Inverter.
Model: ACS800-01-0006-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 10.9A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 13.8A.
Typical motor power in no-overload use: 4KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10.2A.
Typical motor power in light-overload use: 4Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.5A.
Typical motor power in heavy-duty use: 3KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0002-2
Product Name: Inverter.
Model: ACS800-01-0002-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 6.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Frame size: R2.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 6.0A.
Typical motor power in light-overload use: 1.1Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 4.3A.
Typical motor power in heavy-duty use: 0.75KW.
Typical motor power in no-overload use: 1.5KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mennekes Receptacle 3770
Product Name:Receptacles
Part No.:3770.
Ampere:32A.
Poles:3p.
Voltage:230V.
Earth position:6h.
Hertz50-60 Hz.
Connection technology:screw terminals.
Contact:standard.
Protection type:IP67.
screw terminals.
highly resistant to chemicals
highly heat resistant contact carrier
nickel plated contacts
with 4 external fixings
one cable entry at top, one blind cable entry (can be cut out) at bottom
Mennekes AMAXX receptacle combination 920277
Product Name:AMAXX? receptacle combination
Part No.:920277.
Fitted with:1 swiss standard type 25, 16A, 5p, 400V
2 swiss standard type 23, 16A, 3p, 230V.
Fusing:1 RCD 40A, 4p, 0.03A
1 MCB 16A, 3p, C
2 MCB′s 16A, 1p, C.
Pre-fuse max.:63A.
InA:29A.
RDF:0.9.
Connection/feeder cable:for 1 cable up to 5 x 10mm2.
Enclosure size:260 x 225 mm (H x W).
Protection type IP44.
pre-wired for installation.
hinged to the side.
enclosure and insert made of AMAPLAST.
fusing behind a transparent cover.