Home >> Products >> 55
Proface HMI AGP3600-T1-AF-D81C
Product Name: HMI(w/dicrete i/o).
Model: AGP3500-T1-AF-D81C(Source).
Display Type and Size: TFT Color LCD(12.1in).
Graphic Display Resolution: 800*600 pixels(VGA).
Backlight: LED OR CCFL.
Display Area: W248 x H186.5 mm [W9.76 x H7.34 in].
CF Card: 1 slot, type II.
Serial Ports (COM1): RS-232C/422/485.
Touch Screen: Resistive Film(analog).
Display Colors: 65536 COLRS(NO Blink)/16384 colors(blink).
Programming Memory: 16mb flash EPROM.
Input Voltage: 24 VDC.
Ethernet: yes.
ABB Inverter ACS800-01-0040-3
Product Name: Inverter.
Model: ACS800-01-0040-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 72A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 86A.
Typical motor power in no-overload use: 37KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 69A.
Typical motor power in light-overload use: 30Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 22KW.
Frame size: R5.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 49A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0030-5
Product Name: Inverter.
Model: ACS800-01-0030-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 42A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 62A.
Typical motor power in no-overload use: 22KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 39A.
Frame size: R4.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 32A.
Typical motor power in heavy-duty use: 18.5KW.
Typical motor power in light-overload use: 22Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS550-01-04A1-4
Product Name: Inverter.
Model: ACS550-01-04A1-4.
Typical motor power in 400 V at heavy-duty use: 1.1KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 1.5kw.
Typical motor power in 460 V at normal use: 2hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 4.1A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 1.5HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 3.3A.
Frame size: R1.
Proface HMI(Control) LT3300-T1-D24-K
Product Name: HMI(Control).
Model: LT3300-T1-D24-K(sink).
Display Type and Size: TFT Color LCD(5.7in).
Graphic Display Resolution: 320*240 pixels(QVGA).
Touch Screen: Resistive Film(analog).
Display Area: W115.2mm x H86.4mm [4.54in x 3.4in].
Built in DIO (Input): 16 points.
Built in DIO (Output): 16 points.
Display Colors: 65536 COLRS(NO Blink)/16384 colors(blink).
Backlight: whilte led.
Programming Memory: 6mb flash EPROM.
Input Voltage: 24 VDC.
Serial: RS232C/422/485.
Ethernet: yes.
I/O Expansion: 3 EXM Modules.
Mitsubishi Human-Machine Interface GT2510-VTWD
Product Name: Human-Machine Interface.
Model: GT2510-VTWD.
Power supply: 24VDC.
Panel color: Black.
Display device: TFT color LCD 65536 colors.
Screen size: 10.4 inch.
Resolution: SVGA: 640 × 480 dots.
Display size (W × H): 211.2 × 158.4 mm (8.315 × 6.236 inch).
Backlight: White LED (not replaceable).
ABB Inverter ACS550-01-015A-4
Product Name: Inverter.
Model: ACS550-01-015A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 7.5kw.
Typical motor power in 460 V at normal use: 10hp.
Frame size: R2.
Typical motor power in 400 V at heavy-duty use: 5.5KW.
Typical motor power in 460 V at heavy-duty use: 7.5HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 11.9A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 15.4A.
ABB Inverter ACS550-01-246A-4
Product Name: Inverter.
Model: ACS550-01-246A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 400 V at normal use: 132kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 192A.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 246A.
Typical motor power in 400 V at heavy-duty use: 110KW.
Typical motor power in 460 V at heavy-duty use: 150HP.
Typical motor power in 460 V at normal use: 200hp.
Frame size: R6.
ABB Inverter ACS550-01-059A-4
Product Name: Inverter.
Model: ACS550-01-059A-4.
Typical motor power in 400 V at heavy-duty use: 22KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 30kw.
Typical motor power in 460 V at normal use: 40hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 59A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 30HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 45A.
Frame size: R4.
611 Results 12/Page Page 9 of 51     [First Page] << Previous 5 6 7 8 9 10 11 12 13 14 Next >> [Last Page]