Home >> Products >> 35
ABB Inverter ACS355-03X-07A3-4
Product Name: Inverter.
Model: ACS355-03X-07A3-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 3.0kw.
Current rating represents the rated continuous drive output current inside the drive specification.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 7.3A.
Frame size: R1.
Typical motor power in 460 V at normal use: 3.0hp.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
Proface HMI AGP3600-T1-AF-D81C
Product Name: HMI(w/dicrete i/o).
Model: AGP3500-T1-AF-D81C(Source).
Display Type and Size: TFT Color LCD(12.1in).
Graphic Display Resolution: 800*600 pixels(VGA).
Backlight: LED OR CCFL.
Display Area: W248 x H186.5 mm [W9.76 x H7.34 in].
CF Card: 1 slot, type II.
Serial Ports (COM1): RS-232C/422/485.
Touch Screen: Resistive Film(analog).
Display Colors: 65536 COLRS(NO Blink)/16384 colors(blink).
Programming Memory: 16mb flash EPROM.
Input Voltage: 24 VDC.
Ethernet: yes.
ABB Inverter ACS800-01-0255-5
Product Name: Inverter.
Model: ACS800-01-0255-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 290A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 351A.
Typical motor power in no-overload use: 200KW
Frame size: R6.
Typical motor power in light-overload use: 200Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 234A.
Typical motor power in heavy-duty use: 160KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 285A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mitsubishi Input/Output module A0J2-E56AS
Product: Input/Output module.
Model: A0J2-E56AS.
Outline: Input: 32 points, 100 to 120 V AC, 10 mA, response time: 35 ms
Output: 24 points, 100 to 240 V AC, leakage at OFF: 3 mA, response time: 0.5 Hz+1 ms, 8 points/common, with fuse and surge suppressor, 36-point terminal block.
Proface HMI(Control) LT3201-A1-D24-K
Product Name: HMI(Control).
Model: LT3201-A1-D24-K(sink).
Display Type and Size: Monchrome amber/red lcd(3.8in).
Graphic Display Resolution: 320*240 pixels(QVGA).
Touch Screen: Resistive Film(analog).
Display Area: W78.8mm x H59.6mm [3.10in x 2.35in].
Input Voltage: 24 VDC.
Built in DIO (Output): 6 points.
Display Colors: monochrome(8 levels).
Backlight: amber/red led.
Programming Memory: 6mb flash EPROM.
Built in DIO (Input): 12 points.
Mitsubishi Remote I/O module AJ72PT35
Model: AJ72PT35.
Remote I / O module optical data links shared with twisted.
Cable / twisted pair fiber optic cable.
Single loop.
Remote station I / O.
Size: 250(H)×37.5(W)×111(D)mm.
Weight: 0.6kg.
Mennekes Stainless steel receptacle combination 83706
Product Name:Stainless steel receptacle combination
Part No.:83706.
Fitted with:1 CEE 63A, 5p, 400V
1 CEE 32A, 5p, 400V
1 CEE 16A, 5p, 400V
4 SCHUKO? 16A, 230V.
Fusing:2 RCD′s 63A, 4p, 0.03A
2 MCB′s 63A, 3p, C
1 MCB 32A, 3p, C
1 MCB 16A, 3p, C
4 MCB′s 16A, 1p, B.
Pre-fuse max:125A.
InA :72A.
RDF:0.5.
Connection/feeder cable:for 2 cable up to 5 x 50mm2.
Enclosure size:700 x 530 x 350 mm (H x W x D).
Protection type IP44.
stainless steel enclosure (material 1.4301).
surface with a flat finish (K240), material 1.4571 on request.
protection type IP 44 with closed door.

Mennekes EverGUM receptacle combination 70106
Product Name:EverGUM receptacle combination
Part No.:70106.
Fitted with:1 CEE 32A, 5p, 400V
6 SCHUKO? 16A, 230V.
Fusing:1 RCD 40A, 4p, 0.03A
3 MCB′s 16A, 1p, B.
Pre-fuse max:32A.
InA:26A.
RDF:0.4.
Connection/feeder cable:2 m H07RN-F5G4 with CEE-plug 32A, 5p, 400V.
Enclosure size:445 x 135 mm (H x W).
Protection type IP44.
solid rubber enclosure, signal yellow RAL 1003.
pre-wired for installation.
404 Results 12/Page Page 8 of 34     [First Page] << Previous 4 5 6 7 8 9 10 11 12 13 Next >> [Last Page]