Home >> Products >> 110
ABB Inverter ACS800-01-0011-7
Product Name: Inverter.
Model: ACS800-01-0011-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 13A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 14A.
Typical motor power in no-overload use: 11KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 11.5A.
Frame size: R4.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 8.5A.
Typical motor power in heavy-duty use: 5.5KW.
Typical motor power in light-overload use: 7.5Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0004-5
Product Name: Inverter.
Model: ACS800-01-0004-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 4.9A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
Typical motor power in no-overload use: 2.2KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.5A.
Typical motor power in light-overload use: 2.2Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 1.5KW.
Frame size: R2.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0050-3
Product Name: Inverter.
Model: ACS800-01-0050-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 86A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 112A.
Typical motor power in no-overload use: 45KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 80A.
Frame size: R5.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 60A.
Typical motor power in heavy-duty use: 30KW.
Typical motor power in light-overload use: 37Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0100-3
Product Name: Inverter.
Model: ACS800-01-0100-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 166A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 202A.
Typical motor power in no-overload use: 90KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 155A.
Typical motor power in light-overload use: 75Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 55KW.
Frame size: R6.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 115A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0060-2
Product Name: Inverter.
Model: ACS800-01-0060-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 166A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 202A.
Typical motor power in no-overload use: 45KW
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Typical motor power in light-overload use: 45Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 115A.
Typical motor power in heavy-duty use: 30KW.
Frame size: R6.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 155A.
ABB Inverter ACS800-01-0004-2
Product Name: Inverter.
Model: ACS800-01-0004-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 10.9A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Typical motor power in light-overload use: 2.2Kw.
Typical motor power in no-overload use: 2.2KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10.2A.
Phd: 13.8A.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.5A.
Typical motor power in heavy-duty use: 1.5KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mitsubishi Inverter FR-F740-S185K
Product Name: Inverter.
Model: FR-F740-S185K.
185 KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 185 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 275 kVA
Cooling system: Forced air cooling.
Approx. mass: 110 Kg.
ABB Inverter ACS800-01-0040-7
Product Name: Inverter.
Model: ACS800-01-0040-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 36A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 54A.
Typical motor power in no-overload use: 30KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in light-overload use: 30Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 27A.
Typical motor power in heavy-duty use: 22KW.
Frame size: R4.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 34A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
404 Results 12/Page Page 7 of 34     [First Page] << Previous 3 4 5 6 7 8 9 10 11 12 Next >> [Last Page]