Home >> Products >> 77
Mennekes Plug 7716
Product Name:Plug
Part No.7716.
Ampere:16A.
Poles:4P.
Voltage:400V.
Earth position:6h.
Hertz:50-60 Hz.
Connection technology :Screw terminals.
Contact:standard.
screw terminals.
identification acc. to 94/9/EG: II 3D Ex tD A22 T80°C.
dust ignition protection type provided: Ex de IIC T6.
enclosure: impact resistant polyamide.
permissible ambient temperature: -25°C to +45°C.
Mennekes Plug 7776
Product Name:Plug
Part No.7776.
Ampere:125A.
Poles:4P.
Voltage:400V.
Earth position:6h.
Hertz:50-60 Hz.
Connection technology :Screw terminals.
Contact:standard.
screw terminals.
identification acc. to 94/9/EG: II 3D Ex tD A22 T80°C.
dust ignition protection type provided: Ex de IIC T6.
enclosure: impact resistant polyamide.
permissible ambient temperature: -25°C to +45°C.
Mennekes Plug 7786
Product Name:Plug
Part No.7786.
Ampere:125A.
Poles:5P.
Voltage:400V.
Earth position:6h.
Hertz:50-60 Hz.
Connection technology :Screw terminals.
Contact:standard.
screw terminals.
identification acc. to 94/9/EG: II 3D Ex tD A22 T80°C.
dust ignition protection type provided: Ex de IIC T6.
enclosure: impact resistant polyamide.
permissible ambient temperature: -25°C to +45°C.
Mennekes Receptacle combination 97719
Product Name:Receptacle combination
Part No.:97719.
Ampere:16A.
Poles:5p.
Voltage:400V.
Hertz50-60 Hz.
Protection type:IP44.
screw terminals.
CEE- and receptacle SCHUKO? in one enclosure
receptacle SCHUKO? fused with 1 MCB 16A, 1p, C
ABB Inverter ACS800-01-0025-3
Product Name: Inverter.
Model: ACS800-01-0025-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 44A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 62A.
Frame size: R4.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 41A.
Typical motor power in light-overload use: 18.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 32A.
Typical motor power in heavy-duty use: 15KW.
Typical motor power in no-overload use: 22KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0020-7
Product Name: Inverter.
Model: ACS800-01-0020-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 22A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 28A.
Typical motor power in no-overload use: 18.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 20A.
Typical motor power in light-overload use: 15Kw.
Frame size: R4.
Typical motor power in heavy-duty use: 11KW.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 15A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0105-5
Product Name: Inverter.
Model: ACS800-01-0105-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 145A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 170A.
Typical motor power in no-overload use: 90KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in light-overload use: 90Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 100A.
Typical motor power in heavy-duty use: 55KW.
Frame size: R5.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 141A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0140-5
Product Name: Inverter.
Model: ACS800-01-0140-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 180A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 282A.
Frame size: R6.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 163A.
Typical motor power in light-overload use: 110Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 141A.
Typical motor power in heavy-duty use: 90KW.
Typical motor power in no-overload use: 110KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
163 Results 12/Page Page 6 of 14     [First Page] << Previous 2 3 4 5 6 7 8 9 10 11 Next >> [Last Page]