Mitsubishi Temperature input Module A1S62RD4N
Product: Temperature input Module.
Model: A1S62RD4N.
Outline: 2 channels, 4-wire type platinum RTD (Pt100 [JIS C1604-1997, IEC 751-am2, JIS C1604-1989, DIN 43760-1980], JPt100 [JIS C1604-1981]), coNVersion speed: 40 ms/channel, 20-point terminal block.
Mitsubishi INVerter FR-A840-12120-2-60
Product Name: INVerter.
Model: FR-A840-12120-2-60.
500KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity(SLD): 630 kW.
Rated input AC voltage/frequency: Three-phase 380 to 500 V 50 Hz/60 Hz.
Cooling system: Forced air cooling.
Approx. mass: 243 Kg.
ABB INVerter ACS800-01-0025-2
Product Name: INVerter.
Model: ACS800-01-0025-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 72A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 86A.
Typical motor power in no-overload use: 18.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 69A.
Typical motor power in light-overload use: 18.5Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 11KW.
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 49A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB INVerter ACS800-01-0030-2
Product Name: INVerter.
Model: ACS800-01-0030-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 86A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Typical motor power in heavy-duty use: 15KW.
Typical motor power in no-overload use: 22KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 80A.
Typical motor power in light-overload use: 22Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 60A.
Phd: 112A.
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.