Home >> Products >> 150
ABB Inverter ACS800-01-0040-5
Product Name: Inverter.
Model: ACS800-01-0040-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 48A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 72A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 44A.
Typical motor power in light-overload use: 30Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 36A.
Typical motor power in heavy-duty use: 22KW.
Frame size: R4.
Typical motor power in no-overload use: 30KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0205-7
Product Name: Inverter.
Model: ACS800-01-0205-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 190A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 245A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 180A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 147A.
ABB Inverter ACS550-01-180A-4
Product Name: Inverter.
Model: ACS550-01-180A-4.
Typical motor power in 460 V at normal use: 150hp.
Wall-mounted units.
Typical motor power in 400 V at normal use: 90kw.
3-phase supply voltage 380 to 480 V.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 180A.
Typical motor power in 400 V at heavy-duty use: 75KW.
Typical motor power in 460 V at heavy-duty use: 125HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 156A.
Frame size: R6.
Mennekes Wall mounted receptacle 7150
Product Name:Wall mounted receptacle
Part No.:7150.
Ampere:16A.
Poles:5p.
Voltage:400V.
Earth position :6h.
Hertz50-60 Hz.
Connection technology:screw terminals.
Contact: standard
Protection type:IP67.
screw terminals.
fused with RCD (0.03A).
other leakage current ratings on request.
214 Results 12/Page Page 5 of 18     << Previous 1 2 3 4 5 6 7 8 9 10 Next >> [Last Page]