Home >> Products >> 55
Proface HMI AGP3500-T1-AF-D81C
Product Name: HMI(w/dicrete i/o).
Model: AGP3500-T1-AF-D81C(Source).
Display Type and Size: TFT Color LCD(10.4in).
Graphic Display Resolution: 640*480 pixels(VGA).
Display Colors: 65536 COLRS(NO Blink)/16384 colors(blink).
Display Area: W153.7 x H115.8 mm [W6.05 x H4.56 in].
Ethernet: yes.
Serial Ports (COM1): RS-232C/422/485.
Touch Screen: Resistive Film(analog).
Backlight: LED OR CCFL.
Programming Memory: 16mb flash EPROM.
Input Voltage: 100-240VDC.
CF Card: 1 slot, type II.
ABB Inverter ACS355-03X-02A4-2
Product Name: Inverter.
Model: ACS355-03X-02A4-2.
3-phase AC supply, 200 to 240 V.
Typical motor power in 400 V at normal use: 0.37kw.
Current rating represents the rated continuous drive output current inside the drive specification.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 2.4A.
Frame size: R0.
Typical motor power in 460 V at normal use: 0.5hp.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-03A5-2
Product Name: Inverter.
Model: ACS355-03X-03A5-2.
Current rating represents the rated continuous drive output current inside the drive specification.
Typical motor power in 400 V at normal use: 0.55kw.
Typical motor power in 460 V at normal use: 0.75hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 3.5A.
Frame size: R0.
3-phase AC supply, 200 to 240 V.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-17A6-2
Product Name: Inverter.
Model: ACS355-03X-17A6-2.
3-phase AC supply, 200 to 240 V.
Typical motor power in 400 V at normal use: 4.0kw.
This code states the factory installed SW variants to the drive.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 17.6A.
Frame size: R2.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 460 V at normal use: 5.0hp.
ABB Inverter ACS355-03X-01A9-4
Product Name: Inverter.
Model: ACS355-03X-01A9-4.
Typical motor power in 460 V at normal use: 0.75hp.
Typical motor power in 400 V at normal use: 0.55kw.
3-phase AC supply, 380 to 480 V.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 1.9A.
Frame size: R0.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-05A6-4
Product Name: Inverter.
Model: ACS355-03X-05A6-4.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 400 V at normal use: 2.2kw.
Typical motor power in 460 V at normal use: 3.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 5.6A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
3-phase AC supply, 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS355-03X-23A1-4
Product Name: Inverter.
Model: ACS355-03X-23A1-4.
3-phase AC supply, 380 to 480 V.
Typical motor power in 400 V at normal use: 11.0kw.
Frame size: R3.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 23.1A.
Typical motor power in 460 V at normal use: 15.0hp.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
This code states the factory installed SW variants to the drive.
ABB Inverter ACS800-01-0001-2
Product Name: Inverter.
Model: ACS800-01-0001-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Frame size: R2.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
Typical motor power in no-overload use: 1.1KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.7A.
Typical motor power in light-overload use: 0.75Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
Typical motor power in heavy-duty use: 0.55KW.
Rated current available continuously without overloadability at 40 °C: 5.1A
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0003-2
Product Name: Inverter.
Model: ACS800-01-0003-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 8.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 1.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 1.5Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 1.1KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
611 Results 12/Page Page 40 of 51     [First Page] << Previous 36 37 38 39 40 41 42 43 44 45 Next >> [Last Page]