Home >> Products >> 94
Mennekes AMAXX receptacle combination 940744
Product Name:AMAXX? receptacle combination
Part No.:940744.
Fitted with:1 CEE 16A, 5p, 400V
2 french/belg. standard 16A, 2p+E, 230V
1 CEE 16A, 2p, 20-25V.
Fusing:1 RCD 40A, 4p, 0.03A
1 MCB 16A, 3p+N, C
1 MCB 16A, 1p+N, C
1 single phase transformer 160VA, 230V/24V
1 MCB 6A, 2p, C
1 MCB 4A, 1p+N, C.
Pre-fuse max:100A.
InA :26A.
RDF:0.6.
Connection/feeder cable:for 2 cable up to 5 x 25mm2.
Enclosure size:520 x 225 mm (H x W).
Protection type IP44.
pre-wired for installation.
hinged to the side.
enclosure and insert made of AMAPLAST.
fusing behind a transparent cover.
ABB Inverter ACS800-01-0205-5
Product Name: Inverter.
Model: ACS800-01-0205-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 260A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 215A.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 254A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0016-3
Product Name: Inverter.
Model: ACS800-01-0016-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 32A.
Typical motor power in no-overload use: 11KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 24A.
Frame size: R3.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
Typical motor power in heavy-duty use: 7.5KW.
Typical motor power in light-overload use: 11Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0205-3
Product Name: Inverter.
Model: ACS800-01-0205-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 290A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 351A.
Typical motor power in no-overload use: 160KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 234A.
Typical motor power in heavy-duty use: 132KW.
Frame size: R6.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 285A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0020-2
Product Name: Inverter.
Model: ACS800-01-0020-2.
Frame size: R4.
Rated current available continuously without overloadability at 40 °C: 55A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 72A.
Typical motor power in no-overload use: 15KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 50A.
Typical motor power in light-overload use: 15Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 37A.
Typical motor power in heavy-duty use: 7.5KW.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mitsubishi Ethernet Modle A1SJ71E71N-B5
Model : A1SJ71E71N-B5.
Interface: 10BASE5.
Data transmission rate: 10Mbps.
Size: 130(H)×34.5(W)×94(D)mm.
Weight: 0.19kg.
Mennekes AMAXX receptacle combination 943510
Product Name:AMAXX? receptacle combination
Part No.:943510.
Fitted with:4 french/belg. standard 16A, 2p+E, 230V.
Fusing:1 RCD 40A, 4p, 0.03A
1 MCB 32A, 3p+N, C
1 MCB 16A, 3p+N, C
1 MCB 16A, 1p+N, C
1 off button.
Pre-fuse max:40A.
InA :38A.
RDF:0.45.
Connection/feeder cable:for 2 cable up to 5 x 25mm2.
Enclosure size:520 x 225 mm (H x W).
Protection type IP44.
pre-wired for installation.
hinged to the side.
enclosure and insert made of AMAPLAST.
fusing behind a transparent cover.
Mennekes Wall mounted receptacle 7806
Product Name:Wall mounted receptacle
Part No.7806.
Ampere:16A.
Poles:3P.
Voltage:230V.
Earth position:6h.
Hertz:50-60 Hz.
Connection technology :Screw terminals.
Contact:standard.
screw terminals.
all-pole ON/OFF switching by turning the plug.
identification acc. to 94/9/EG: II 3D Ex tD A22 T80°C.
dust ignition protection type provided: Ex de IIC T6.
cable entry 1x Ex-cable gland and 1x Ex-screw plug made of plastic at bottom.
enclosure: glass-fibe reinforced polyester.
permissible ambient temperature: -25°C to +45°C.
Mennekes AMAXX receptacle combination 940008
Product Name:AMAXX? receptacle combination
Part No.:940008.
Fitted with:2 CEE 32A, 5p, 400V
3 SCHUKO? 16A, 230V.
Fusing:1 RCD 63A, 4p, 0.03A
2 MCB′s 32A, 3p, C
3 MCB′s 16A, 1p, C.
Pre-fuse max.:63A.
InA:48A.
RDF:0.6.
Connection/feeder cable:for 2 cable up to 5 x 25 mm2.
Enclosure size:520 x 225 mm (H x W).
Protection type IP44.
pre-wired for installation.
hinged to the side.
enclosure and insert made of AMAPLAST.
fusing behind a transparent cover.
ABB Inverter ACS800-01-0205-7
Product Name: Inverter.
Model: ACS800-01-0205-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 190A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 245A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 180A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 147A.
Mennekes Wall mounted receptacle 1194
Product Name:Wall mounted receptacle.
Part No.:1194.
Ampere:16A.
Poles:4p.
Voltage:110V.
Earth position:4h.
Hertz:50-60 Hz.
Connection technology:screw terminals.
Contact:standard.
Protection type:IP67.
screw terminals.
four external fixing holes.
one cable entry at top and one blind cable entry (can be cut out) at bottom.
receptacles are designed for adding an auxiliary contact switch.
150 Results 12/Page Page 4 of 13     << Previous 1 2 3 4 5 6 7 8 9 10 Next >> [Last Page]