Home >> Products >> 25
OMRON CPU CQM1-CPU42-V1
Product name: CQM1 CPU.
Model: CQM1-CPU42-V1.
I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Analog setting: YES.
Mitsubishi Relay Output module AY13
Model: AY13.
Contact output: 32 points, DC24V/AC240V, 2A/1 point, 5A / 1 common.
Response time: 12ms.
8 points per common.
38-point terminal block.
Size: 250(H)×37.5(W)×131(D)mm.
Weight: 0.59kg.
Mitsubishi Analog - digital conversion module A68AD
Model: A68AD.
8 channels.
Input: DC-10 ~ 10V, DC4 ~ 20mA.
Output (resolution): -2000 to 2000.
Conversion rate: 2.5ms / 1 channel.
Terminal 38 points.
Size: 250(H)×37.5(W)×131(D)mm.
Weight: 0.60kg.
Mitsubishi Temperature - Digital Conversion Unit A68RD4N
Model: A68RD4N.
8-channel
Wire platinum RTD 4 (Pt100 (JIS C1604-1989, DIN 43760-1980), JPt100 (JIS C1604-1981)).
Conversion rate: 40ms / 1 Channel
38-point terminal block.
Size: 250(H)×37.5(W)×131(D)mm.
Weight: 0.62kg.
Mitsubishi Ethernet interface module AJ71QE71N-B5T
Model: AJ71QE71N-B5T.
Interface: 10BASE-T/10BASE5.
Size: 250(H)×37.5(W)×106(D)mm.
Weight: 0.35kg.
Mitsubishi CPU A0J2HCPUR21
Product:CPU.
Model:A0J2HCPUR21.
Outline:No.ofI/Opoints:480points,no.ofI/Odevicepoints:480points,programcapacity:8ksteps,basicinstructionprocessingspeed(LDinstruction):1.25μs,RAMmemorycapacity:32KB,built-inpowersupply,
withcoaxialdatalinkfunction.
ABB Inverter ACS550-01-038A-4
Product Name: Inverter.
Model: ACS550-01-038A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 400 V at heavy-duty use: 15KW.
Typical motor power in 400 V at normal use: 18.5kw.
Typical motor power in 460 V at normal use: 25hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 38A.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 20HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31A.
Frame size: R3.
ABB Inverter ACS800-01-0020-3
Product Name: Inverter.
Model: ACS800-01-0020-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 34A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 46A.
Typical motor power in no-overload use: 15KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 15Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 23A.
Typical motor power in heavy-duty use: 11KW.
Frame size: R3.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 31A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0006-5
Product Name: Inverter.
Model: ACS800-01-0006-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 8.1A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 4KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 4Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.6A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 3KW.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mennekes Cepex wall mounted receptacle 4101
Product Name:Cepex wall mounted receptacle
Part No.:4101.
Ampere:16A.
Poles:3p.
Voltage:110V.
Earth position 4h.
Hertz 50-60Hz.
Protection type IP44.
screw terminals.
cable entry: 1 x M 25 with cable gland at top, 1 x M 25 to be cut out at the bottom, 1 x M 20 to be cut out at the back side, for cables 7 up to 13 mm ?.
meeting DIN 18032 standards for ball rebound.
1450 Results 12/Page Page 32 of 121     [First Page] << Previous 28 29 30 31 32 33 34 35 36 37 Next >> [Last Page]