ABB Inverter ACS800-01-0040-7
Product Name: Inverter.
Model: ACS800-01-0040-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 36A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 54A.
Typical motor power in no-overload use: 30KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in light-overload use: 30Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 27A.
Typical motor power in heavy-duty use: 22KW.
Frame size: R4.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 34A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0020-7
Product Name: Inverter.
Model: ACS800-01-0020-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 22A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 28A.
Typical motor power in no-overload use: 18.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 20A.
Typical motor power in light-overload use: 15Kw.
Frame size: R4.
Typical motor power in heavy-duty use: 11KW.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 15A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0105-5
Product Name: Inverter.
Model: ACS800-01-0105-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 145A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 170A.
Typical motor power in no-overload use: 90KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in light-overload use: 90Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 100A.
Typical motor power in heavy-duty use: 55KW.
Frame size: R5.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 141A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0025-7
Product Name: Inverter.
Model: ACS800-01-0025-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 38A.
Typical motor power in no-overload use: 22KW
Frame size: R4.
Typical motor power in light-overload use: 18.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
Typical motor power in heavy-duty use: 15KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 23A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0070-5
Product Name: Inverter.
Model: ACS800-01-0070-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 96A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 138A.
Typical motor power in heavy-duty use: 45KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 88A.
Typical motor power in light-overload use: 55Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 69A.
Typical motor power in no-overload use: 55KW
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mennekes Wall mounted receptacle 1424
Product Name:Wall mounted receptacle
Part No.:1424.
Ampere:32A.
Poles:4p.
Voltage:230V.
Earth position:9h.
Hertz:50-60 Hz.
Connection technology:screw terminals.
Contact:standard.
Protection type:IP44.
screw terminals.
internal fixing.
one cable entry at top, two blind cable entries (can be cut out) at bottom.
enclosure base can be turned 180°.
receptacles are designed for adding an auxiliary contact switch..
ABB Inverter ACS800-01-0005-5
Product Name: Inverter.
Model: ACS800-01-0005-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 6.2A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Typical motor power in no-overload use: 3KW
Frame size: R2.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 4.2A.
Typical motor power in heavy-duty use: 2.2KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 5.6A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0005-3
Product Name: Inverter.
Model: ACS800-01-0005-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 8.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 3KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
Typical motor power in heavy-duty use: 2.2KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0006-3
Product Name: Inverter.
Model: ACS800-01-0006-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 10.9A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 13.8A.
Typical motor power in no-overload use: 4KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10.2A.
Typical motor power in light-overload use: 4Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.5A.
Typical motor power in heavy-duty use: 3KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.