Mitsubishi Inverter FR-A840-06830-2-60
Product Name: Inverter.
Model: FR-A840-06830-2-60.
280KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity(SLD): 355 kW.
Rated input AC voltage/frequency: Three-phase 380 to 500 V 50 Hz/60 Hz.
Cooling system: Forced air cooling.
Approx. mass: 166 Kg.
Proface HMI AGP3500-T1-D24-FN1M
Product Name: HMI(W/FlexNetwork).
Model: AGP3500-T1-D24-FN1M.
Display Type and Size: TFT Color LCD(10.4in).
Graphic Display Resolution: 640*480 pixels(VGA).
Input Voltage: 24 VDC.
Display Area: W211.2 x H158.4 mm [W8.31 x H6.24 in].
CF Card: 1 slot, type II.
Serial Ports (COM1): RS-232C/422/485.
Touch Screen: Resistive Film(analog).
Backlight: CCFL.
Programming Memory: 8mb flash EPROM.
Display Colors: 65536 COLRS(NO Blink)/16384 colors(blink).
Ethernet: yes.
Mitsubishi Inverter FR-F740-55K
Product Name: Inverter.
Model: FR-F740-55K.
55 KW.
Rated voltage: Three-phase 380 to 500 V.
Applicable motor capacity: 55 kW.
Permissible AC voltage fluctuation: 323 to 528V 50Hz/60Hz.
Power supply capacity: 100 kVA
Cooling system: Forced air cooling.
Approx. mass: 37 Kg.
ABB Inverter ACS550-01-157A-4
Product Name: Inverter.
Model: ACS550-01-157A-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Typical motor power in 460 V at heavy-duty use: 100HP.
Typical motor power in 460 V at normal use: 125hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 157A.
Typical motor power in 400 V at heavy-duty use: 55KW.
Typical motor power in 400 V at normal use: 75kw.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 125A.
Frame size: R6.
ABB Inverter ACS550-01-290A-4
Product Name: Inverter.
Model: ACS550-01-290A-4.
Typical motor power in 400 V at heavy-duty use: 132KW.
Wall-mounted units.
Typical motor power in 400 V at normal use: 160kw.
Typical motor power in 460 V at normal use: 200hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 290A.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 200HP.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 246A.
Frame size: R6.
ABB Inverter ACS550-02-368A-4
Product Name: Inverter.
Model: ACS550-01-368A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 250HP.
Typical motor power in 400 V at normal use: 200kw.
Typical motor power in 460 V at normal use: 300hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 368A.
Typical motor power in 400 V at heavy-duty use: 160KW.
Free-standing units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 302A.
Frame size: R8.
ABB Inverter ACS550-02-526A-4
Product Name: Inverter.
Model: ACS550-01-526A-4.
3-phase supply voltage 380 to 480 V.
Typical motor power in 460 V at heavy-duty use: 400HP.
Typical motor power in 400 V at normal use: 280kw.
Typical motor power in 460 V at normal use: 450hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 526A.
Typical motor power in 400 V at heavy-duty use: 250KW.
Free-standing units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 477A.
Frame size: R8.
ABB Inverter ACS550-01-08A8-4
Product Name: Inverter.
Model: ACS550-01-08A8-4.
3-phase supply voltage 380 to 480 V.
Wall-mounted units.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 6.9A
Typical motor power in 460 V at normal use: 5.4hp.
Continuous rms current. 10% overload is allowed for one minute in ten minutes: 8.8A.
Typical motor power in 400 V at heavy-duty use: 3KW.
Typical motor power in 460 V at heavy-duty use: 4HP.
Typical motor power in 400 V at normal use: 4kw..
Frame size: R1.
ABB Inverter ACS355-03X-08A8-4
Product Name: Inverter.
Model: ACS355-03X-08A8-4.
3-phase AC supply, 380 to 480 V.
This code states the factory installed SW variants to the drive.
Typical motor power in 460 V at normal use: 5.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 8.8A.
Frame size: R1.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
Typical motor power in 400 V at normal use: 4.0kw.
ABB Inverter ACS355-03X-31A0-4
Product Name: Inverter.
Model: ACS355-03X-31A0-4.
This code states the factory installed SW variants to the drive.
Typical motor power in 400 V at normal use: 15.0kw.
Typical motor power in 460 V at normal use: 20.0hp.
Continuous rms current. 50% overload is allowed for one minute in ten minutes: 31.0A.
Frame size: R4.
Current rating represents the rated continuous drive output current inside the drive specification.
ACS355 is available in two voltage ranges: 2 = 200 to 240 V and 4 = 380 to 480 V.
3-phase AC supply, 380 to 480 V.
611 Results 12/Page Page 16 of 51     [First Page] << Previous 12 13 14 15 16 17 18 19 20 21 Next >> [Last Page]