Home >> Products >> 25
OMRON Data memory expansion unit CV1000-DM251
Model : CV1000-DM251.
Available CV1000/2000/CVM1-CPU21-V2.
256K words.
Mitsubishi Base unit A33RB
Model: A33RB.
Base unit for a duplex system
3 slots on one side.
Q4AR for redundant system.
Size: 250(H)×570(W)×29(D)mm.
Weight: 2.6kg.
Mitsubishi Base unit A37RHB
Model: A37RHB.
Redundant power supply base unit for.
7 slots on one side.
Q4AR for redundant system.
Size: 250(H)×497(W)×29(D)mm.
Weight: 2.2kg.
Mitsubishi Base unit A38HB
Model: A38HB.
Redundant power supply base unit for.
8 slots.
Mounting unit for QnA series, for fast access.
Size: 250(H)×480(W)×29(D)mm.
Weight: 1.9kg.
Mitsubishi MELSECNET/10 network module AJ71QLP21S
Model: AJ71QLP21S.
Between net MELSECNET/10 PC, / normal station management.
MELSECNET/10 Remote I / O network, remote master station.
Optical loop system.
Connection cable: SI / QSI / H-H broadband PCF /-optic PCF.
Transmission format: double loop.
Function with an external power source..
Size: 250(H)×37.5(W)×111(D)mm.
Weight: 0.39kg.
ABB Inverter ACS800-01-0001-2
Product Name: Inverter.
Model: ACS800-01-0001-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Frame size: R2.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 6.5A.
Typical motor power in no-overload use: 1.1KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 4.7A.
Typical motor power in light-overload use: 0.75Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 3.4A.
Typical motor power in heavy-duty use: 0.55KW.
Rated current available continuously without overloadability at 40 °C: 5.1A
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0003-2
Product Name: Inverter.
Model: ACS800-01-0003-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 8.5A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 1.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 1.5Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 1.1KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0011-2
Product Name: Inverter.
Model: ACS800-01-0011-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 34A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 46A.
Typical motor power in no-overload use: 7.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 31A.
Typical motor power in light-overload use: 7.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 23A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Frame size: R3.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 5.5KW.
ABB Inverter ACS800-01-0025-2
Product Name: Inverter.
Model: ACS800-01-0025-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 72A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 86A.
Typical motor power in no-overload use: 18.5KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 69A.
Typical motor power in light-overload use: 18.5Kw.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in heavy-duty use: 11KW.
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 49A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0030-2
Product Name: Inverter.
Model: ACS800-01-0030-2.
UN = 230 V (Range 208 to 240 V). The power ratings are valid at nominal voltage 230 V.
Rated current available continuously without overloadability at 40 °C: 86A
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Typical motor power in heavy-duty use: 15KW.
Typical motor power in no-overload use: 22KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 80A.
Typical motor power in light-overload use: 22Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 60A.
Phd: 112A.
Frame size: R5.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
1450 Results 12/Page Page 113 of 121     [First Page] << Previous 109 110 111 112 113 114 115 116 117 118 Next >> [Last Page]