Home >> Products >> 97
Mennekes Cepex wall mounted receptacle SCHUKO, grey 4976
Product Name:Cepex wall mounted receptacle SCHUKO?, grey
Part No.:4976.
Ampere :16A
Poles:2p.
Voltage:230V.
Earth position:0h.
Hertz:50-60 Hz.
Shutter:no.
Protection type:IP44.
grey.
screw terminals.
with labelling field.
with safety lock.
two keys.
cannot be dismantled when locked.
on request with identical locks.
cable entry: 1 x M 25 with cable gland at top, 1 x M 25 to be cut out at the bottom, 1 x M 20 to be cut out at the back side, for cables 7 up to 13 mm ?.
with identical locks: part no + index G.
Mennekes Cepex flush mounted receptacle SCHUKO 4974
Product Name:Cepex panel mounted receptacle SCHUKO?
Part No.:4974.
Ampere :16A.
Poles:2p.
Voltage:230V.
Earth position:0h.
Hertz:50-60 Hz.
Shutter:no.
Protection type:IP44.
alpine white or pearl white.
screw terminals.
with labelling field.
suitable for installation in cable ducts and columns.
Mennekes Receptacle combination 97719
Product Name:Receptacle combination
Part No.:97719.
Ampere:16A.
Poles:5p.
Voltage:400V.
Hertz50-60 Hz.
Protection type:IP44.
screw terminals.
CEE- and receptacle SCHUKO? in one enclosure
receptacle SCHUKO? fused with 1 MCB 16A, 1p, C
Mennekes Panel mounted receptacle 997
Product Name:Panel mounted receptacle RAPIDO? with TwinCONTACT
Part No.:997.
Ampere:16A.
Poles:3p.
Voltage:230V.
Earth position :6h.
Hertz 50-60Hz.
Connection technology:Screwless - TwinCONTACT.
Contact: standrad.
Protection type IP44.
screwless spring terminals.
suitable for through wiring.
for wall apertures 61 mm ?.
central fixing.
Mennekes Connector PowerTOP 3971
Product Name:Connector PowerTOP?
Part No.:3971.
Ampere:32A.
Poles:4p
Voltage:500V.
Earth position:7h.
Hertz 50-60Hz.
Connection technology:screw terminals.
Contact:highly heat resistant contact carrier.
Protection type IP44.
screw terminals.
with highly heat resistant contact carrier.
cable gland and external cable grip.
ABB Inverter ACS800-01-0025-7
Product Name: Inverter.
Model: ACS800-01-0025-7.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 38A.
Typical motor power in no-overload use: 22KW
Frame size: R4.
Typical motor power in light-overload use: 18.5Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
Typical motor power in heavy-duty use: 15KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 23A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0140-5
Product Name: Inverter.
Model: ACS800-01-0140-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 180A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 282A.
Frame size: R6.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 163A.
Typical motor power in light-overload use: 110Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 141A.
Typical motor power in heavy-duty use: 90KW.
Typical motor power in no-overload use: 110KW
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0005-5
Product Name: Inverter.
Model: ACS800-01-0005-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 6.2A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 8.2A.
Typical motor power in no-overload use: 3KW
Frame size: R2.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 4.2A.
Typical motor power in heavy-duty use: 2.2KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 5.6A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0005-3
Product Name: Inverter.
Model: ACS800-01-0005-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 8.5A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 3KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 3Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.7A.
Typical motor power in heavy-duty use: 2.2KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0006-3
Product Name: Inverter.
Model: ACS800-01-0006-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 10.9A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 13.8A.
Typical motor power in no-overload use: 4KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 10.2A.
Typical motor power in light-overload use: 4Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 7.5A.
Typical motor power in heavy-duty use: 3KW.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
143 Results 12/Page Page 6 of 12     [First Page] << Previous 2 3 4 5 6 7 8 9 10 11 Next >> [Last Page]