Home >> Products >> 77
ABB Inverter ACS800-01-0040-3
Product Name: Inverter.
Model: ACS800-01-0040-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 72A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 86A.
Typical motor power in no-overload use: 37KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 69A.
Typical motor power in light-overload use: 30Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 22KW.
Frame size: R5.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 49A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0030-5
Product Name: Inverter.
Model: ACS800-01-0030-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 42A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 62A.
Typical motor power in no-overload use: 22KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 39A.
Frame size: R4.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 32A.
Typical motor power in heavy-duty use: 18.5KW.
Typical motor power in light-overload use: 22Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0100-7
Product Name: Inverter.
Model: ACS800-01-0100-7.
Frame size: R6.
Rated current available continuously without overloadability at 40 °C: 93A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 124A.
Typical motor power in no-overload use: 90KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 86A.
Typical motor power in light-overload use: 75Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 62A.
Typical motor power in heavy-duty use: 55KW.
UN = 690 V (Range 525 to 690 V). The power ratings are valid at nominal voltage 690 V.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0006-5
Product Name: Inverter.
Model: ACS800-01-0006-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 8.1A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 10.8A.
Typical motor power in no-overload use: 4KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 7.7A.
Typical motor power in light-overload use: 4Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 5.6A.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Frame size: R2.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Typical motor power in heavy-duty use: 3KW.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0020-3
Product Name: Inverter.
Model: ACS800-01-0020-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 34A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 46A.
Typical motor power in no-overload use: 15KW
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
Typical motor power in light-overload use: 15Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 23A.
Typical motor power in heavy-duty use: 11KW.
Frame size: R3.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 31A.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
Mitsubishi Motion Control Module A1SD774M
Model : A1SD774M.
Number of control axes: 4-axis (axis 2-4 simultaneous, independent 4 axes).
Interpolation: linear interpolation (up to 4 axes).
Control method: PTP (Point To Point), speed control, feeding, speed control, etc.
Control Unit: mm, inch, degree, PULSE.
Mennekes Panel mounted receptacle SCHUKO 10805
Product Name:Panel mounted receptacle SCHUKO?
Part No.:10805.
Ampere :16A.
Poles:2p+E.
Voltage:230V.
Shutter:no.
Connection technology:screw terminals.
Contact:standard.
Protection type:IP68.
screw terminals.
bayonet lock lid attached by a strap.
oval flange.
two fixing holes.
connecting protective caps, part no. 19027706, available on request.
ABB Inverter ACS800-01-0205-5
Product Name: Inverter.
Model: ACS800-01-0205-5.
UN = 500 V (Range 380 to 500 V). The power ratings are valid at nominal voltage 500 V.
Rated current available continuously without overloadability at 40 °C: 260A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 326A.
Typical motor power in no-overload use: 160KW
Frame size: R6.
Typical motor power in light-overload use: 160Kw.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 215A.
Typical motor power in heavy-duty use: 132KW.
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 254A.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
ABB Inverter ACS800-01-0016-3
Product Name: Inverter.
Model: ACS800-01-0016-3.
UN = 400 V (Range 380 to 415 V). The power ratings are valid at nominal voltage 400 V.
Rated current available continuously without overloadability at 40 °C: 25A.
Maximum output current. Available for 10 s at start, otherwise as long as allowed by drive temperature. Note: max. motor shaft power is 150% Phd: 32A.
Typical motor power in no-overload use: 11KW
Continuous current allowing 110% IN for 1 min / 5 min at 40 °C: 24A.
Frame size: R3.
Continuous current allowing 150% Ihd for 1 min / 5 min at 40 °C: 19A.
Typical motor power in heavy-duty use: 7.5KW.
Typical motor power in light-overload use: 11Kw.
ACS800-01 without cable connection box does not ful? ll IP21 requirements.
In -0205-3 and -0255-5 units, H1 is 977 mm and weight is 70 kg.
In -0205-3 and -0255-5 units, H1 is 994 mm, depth 424 mm and weight is 80 kg.
163 Results 12/Page Page 2 of 14     << Previous 1 2 3 4 5 6 7 8 9 10 Next >> [Last Page]